:: PRODUCTS

LOAD
> Custom design
> Shear pin
> Compression
> Tensile
> Torque

> Portable Kits

PRESSURE

CALIBRATION







 

 

Tensile Load Cells

 

Tensile Load cells are produced to fit in the standard shackles range, 12 to 400 tonnes SWL.

Our Tensile load cells are used for measuring tension at dead-end anchor. We also produce tensile load cells as portable kits for weighing and as reference tools.

Full Scale Tensile Load: Typical 1-120 tonn

(FS):                          Other capacities upon request

Maximum Tensile Load at 20°C: FS range x 2, below 25 tonnes.

                                                    FS range x (2....1.33) above 25 t

                                                    FS range x 1.33 above 25 t

Temperature range: -20 to 60°C

Linearity: ± 0,2 % FS

Total accuracy at ambient

temperature, the accuracy

demands correct bolt dimension: Typical 0,5%

TCS (Thermal Compensated

Sensitivity): Typical 0,03% FS x (temp.-amb)

Output: 1-2 mV/V / 4-20mA        

Supply Voltage: Max. 15 VDC / 24 VDC

Electrical Connector: 4 wire / 2 wire

Response time: 2 msec / 13 msec

Bridge Resistance: 4 kohm

Insulation Test: 500 V AC (RMS) > GW

Sealing: IP67

Material: Stainless Steel