Tensile Load Cells
Tensile Load cells are produced to fit in the standard shackles range, 12 to 400 tonnes SWL.
Our Tensile load cells are used for measuring tension at dead-end anchor. We also produce tensile load cells as portable kits for weighing and as reference tools.
Full Scale Tensile Load: Typical 1-120 tonn
(FS): Other capacities upon request
Maximum Tensile Load at 20°C: FS range x 2, below 25 tonnes.
FS range x (2....1.33) above 25 t
FS range x 1.33 above 25 t
Temperature range: -20 to 60°C
Linearity: ± 0,2 % FS
Total accuracy at ambient
temperature, the accuracy
demands correct bolt dimension: Typical 0,5%
TCS (Thermal Compensated
Sensitivity): Typical 0,03% FS x (temp.-amb)
Output: 1-2 mV/V / 4-20mA
Supply Voltage: Max. 15 VDC / 24 VDC
Electrical Connector: 4 wire / 2 wire
Response time: 2 msec / 13 msec
Bridge Resistance: 4 kohm
Insulation Test: 500 V AC (RMS) > GW
Sealing: IP67
Material: Stainless Steel
|