:: PRODUCTS

LOAD
> Custom design
> Shear pin
>> Shear pin LS-3010-SP
>> Shear pin LS-2000-SP
>> Shackle Loadcell
> Compression
> Tensile
> Torque

> Portable Kits

PRESSURE

CALIBRATION








 

 

Shackle load cells

Standard, Exi Shackle Loadcell

The sensor is manufactured to withstand a rough environment. The electronics provide power supply regulation, reverse polarity and over voltage protection. IP-68 upon request. Submersible to 200Bar.

 

 

 

Full Scale Load:              Typical 6-400

(FS)                                 Standard ranges: 12, 17, 25, 35, 55

                                        and 85 tonn

Test Load at 20°C:  FS range x 2, below 25 tonn

                                        FS range x (2...1,33), above 25 tonn

                                        FS range x 1,33 above 200 tonn

Temperature range:       -20°C to 60°C   

Linearity:                        ± 0,5% FS

Total accuracy at

ambient temperature:   +/- 1% of Full Scale

The accuracy demands

correct bolt dimension

TCS:                                Typical 0,03%FS x (temp.-amb)

Output Current:              4-20mA, Current Loop (mV/V)

Supply Voltage:              16-28 VDC (Maximum 15Vdc)

Electrical Connector:     2 wire/4wire

Response time:              12 msec.

Power supply

regulation:                      Yes (For ampl. omly)

Voltage Spike

Protection:                      Yes (For ampl. only)

Polarity Protection:        Yes (For ampl only)

Insulation Test:              500 V C (RMS) > 1 GW

Sealing:                          IP68/Submerisble upon request

Material:                         Stainless Steel

Intrinsic Safe Code:       EEx ia IIC T5, ATEX