Full Scale Load: Typical 6-400
(FS) Standard ranges: 12, 17, 25, 35, 55
and 85 tonn
Test Load at 20°C: FS range x 2, below 25 tonn
FS range x (2...1,33), above 25 tonn
FS range x 1,33 above 200 tonn
Temperature range: -20°C to 60°C
Linearity: ± 0,5% FS
Total accuracy at
ambient temperature: +/- 1% of Full Scale
The accuracy demands
correct bolt dimension
TCS: Typical 0,03%FS x (temp.-amb)
Output Current: 4-20mA, Current Loop (mV/V)
Supply Voltage: 16-28 VDC (Maximum 15Vdc)
Electrical Connector: 2 wire/4wire
Response time: 12 msec.
Power supply
regulation: Yes (For ampl. omly)
Voltage Spike
Protection: Yes (For ampl. only)
Polarity Protection: Yes (For ampl only)
Insulation Test: 500 V C (RMS) > 1 GW
Sealing: IP68/Submerisble upon request
Material: Stainless Steel
Intrinsic Safe Code: EEx ia IIC T5, ATEX |